Comet Executive Gas Repair
7-29
7.6 Burner System
Individual components of the burner system
may wear during normal use and may need
occasional repair, inspection, or adjustment.
If the burner is experiencing problems,
rst inspect and clean the spark plug and pilot
assembly. For more information, refer to Check
and Clean Pilot Assembly on page 4-18.
If the spark plug does not appear to be the
problem, the following procedures also may be
used to resolve the problem:
Burner Removal/Replacement
Burner Tip Maintenance
Temperature Sensor Contact Shoe
Replacement
Temperature Control or High
Temperature Limit Control Replacement
Burner Removal/Replacement
When the ironing cylinder does not heat up
properly, this may be caused by a lint buildup. The
entire gas burner must be removed to completely
clean the gas burner system.
NOTE: Before beginning this
procedure, refer to Heating
System on page 6-12, for other
possible causes/solutions.
Make sure the unit is completely COOL before
beginning this procedure.
NOTE: Take the time to
read through and understand
the entire procedure before
performing this work.
This procedure should be handled
by at least two qualied persons.
Using the “buddy system”
facilitates a quicker procedure
and decreases the risk of
an accident.
Required Tools
Allen wrench: 5/32”
C-clamp: large
Clean cloth
Compressed air
Gloves
Pencil/marker
Pipe thread compound/Teflon
tape
Pipe wrench
Wrenches:
7/16”
9/16” (2)
TOC
INDEX

Table of Contents