Installation Comet Executive Gas
2-6
Locating the Exhaust Blower
NOTE: Proper installation is
required for all warranties and
applicable certication labels to be
valid. Call the factory if you have
any questions.
CAUTION
Do not change the mounting
position of the sail switch
and do not reverse the
blower housing.
The exhaust blower is designed for wall
mounting. Find a good location close to both the
outside discharge point and the unit.
It is particularly important that a straight
section of ductwork be attached directly to the
blower discharge (Figure 2-5, A).
When installed, a blower can be rotated up to
45° to the left or right of vertical to help make
this conguration.
NOTE: Exceeding a 45° rotation
from vertical for the blower may
not maintain proper air movement
and may cause the sail switch to
operate incorrectly.
Installing the Exhaust Blower
Required Tools
Determined locally
1. Install the provided 8” collar in the open-
ing on the top of the exhaust canopy
(Figure 2-6). Bend the tabs back to secure
in position.
2. Install the provided blower outlet rect-
angle-to-round adaptor to the blower
discharge (Figure 2-5, A).
Figure 2-5: The exhaust blower assembly is
designed for remote mounting.
A
B
Figure 2-6: Connect the ducting to the opening on
the top of the exhaust canopy.