Medica EasyStat - Default Chapter; Flow Charts

Medica EasyStat
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ANALYZE QC
FLOWCHA RT 2
FLOWCHA RT 3
If all channels failed
If incorrect barcode scanned
1 *
2 *
3 CALIBRATE
4 DAILY CLEANER
5 SECOND MENU
HOME MENU
1 ANALYZE SAMPLE
2 ANALYZE QC
3 CALIBRATE
4 DAILY CLEANER
5 SECOND MENU
HOME MENU
1 STANDBY
2 REPLACE COMPONENTS
3 DIAGNOSTICS
4 STORED INFORMATION
5 SETUP MENU
6 ADJUST DISPLAY
SECOND MENU
1 LEVEL 1
2 LEVEL 2
3 LEVEL 3
4 Hct LEVEL 1
5 Hct LEVEL 2
6 PROFICIENCY
LIFT SAMPLER TO
ANALYZE
pH PCO
2
PO
2
Hct Na
+
K
+
Ca
++
CALIBRATE
CALIBRATING . . .
DAILY CLEANER
LIFT SAMPLER TO
USE CLEANER
1 REAGENT MODULE
2 ELECTRODES
3 PUMP TUBING
4 SENSOR MODULE/SAMPLER
5 VALVE MODULE
6 SWITCH TO Ca
++
/ Cl-
REPLACE COMPONENTS
1 TEST COMPONENTS
2 TEST FLUIDICS
3 SENSOR STATUS
4 PRIME FLUIDS
5 PRINT mV
s
DIAGNOSTICS
1 PATIENT RESULTS
2 QC RESULTS
3 REFERENCE LIMITS
4 CAL / SAMPLE # DATA
5 REAGENT MODULE
6 PRINTOUTS
STORED INFORMATION
ID
PAT. TEMP 37.0
THb 14.5 g/dL
FIO
2
21%
TIME DRAWN 00.00
ENTER PATIENT DATA 1/2
CONFIRM ?
1 BRIGHTNESS
2 BRIGHTNESS
3 REVERSE
ADJUST DISPLAY
QC HcT LEVEL 1
LOT # XXXXXX
LIFT SAMPLER TO
ANALYZE CONTROL
MANUAL STANDBY
CONFIRM ?
SECURITY CODE
* * * *
CONFIRM ?
QC LEVEL 1
LOT # XXXXXX
LIFT SAMPLER TO
ANALYZE CONTROL
QC LEVEL 1
LOT # XXXXXX
LIFT SAMPLER TO
ANALYZE CONTROL
1 USER OPTIONS
2 CONFIGURATION
3 PRINTER OPTIONS
4 SET REFERENCE LIMITS
5 PATIENT INFORMATION
6 DELETE DATA
SETUP MENU
1 PUMP
2 VALVE
3 SAMPLER SWITCHES
4 DOOR SWITCH
5 REAGENT READER
TEST COMPONENTS
1 REAGENT FLOW
2 SAMPLE FLOW
3 BUBBLE DETECTOR CAL
4 PUMP CAL
TEST FLUIDICS
1 ELECTRODE mVs
2 BAROMETRIC PRESSURE
3 TEMPERATURES
SENSOR STATUS
pH 7.203
PCO
2
32.5 mmHg
PO
2
118 mmol/L
Na
+
140.9 mmol/L
K
+
4.50 mmol/L
Ca
++
2.33 mmol/L
QC LEVEL 1
STORE RESULTS ?
SAMPLE TYPE ARTERIAL
SAMPLE SITE RADIAL
OPERATOR ID?
ENTER PATIENT DATA 2/2
CONFIRM ?
Cl
-
MODE ?
QC HcT LEVEL 1
Hct 55 %
STORE RESULTS ?
1 CALIBRANT A mV
s
2 CALIBRANT B mV
s
3 CALIBRANT C mV
s
ELECTRODE mVs
pH 7.203
PCO
2
32.5 mmHg
PO
2
118 mmol/L
Hct 45%
Na
+
140.1 mmol/L
K
+
4.02 mmol/L
Ca
++
2.33 mmol/L
ANALYSIS RESULTS #001
PATIENT RESULTS
WILL BE LOST
CONFIRM ?
pH 23.99
PCO
2
34.00
PO
2
99.99
Hct 87.34
Na
+
10.78
K
+
41.00
Ca
++
10.00
SLOPES
pH XX.X
PCO
2
XX.X
PO
2
XX.X
Na
+
XX.X
K
+
XX.X
Ca
++
XX.X
ELECTRODE mVs
CALIBRANT A mVs
THb XXX g/dL
pH (T) XXX
PCO
2
(T) XXX mmHg
PO
2
(T) XXX mmHg
TCO
2
XXX mmol/L
HCO
3
XXX mmol/L
BEb
XXX mmol/L
CALCULATED VALUES 1/3
BEecf XXX mmol/L
SBC XXX mmol/L
%sO
2
c XXX
ctO
2
XXX mL/L
CALCULATED VALUES 2/3
CALCULATED VALUES 3/3
Hct XXX.X
ELECTRODE mVs
CALIBRANT A mVs
A-aDO
2
XXX mmHG
RI XXX
Ca
++
(7.4)
XXX mmol/L
Flow Charts
Note: Ca
++
will be replaced by Cl
-
in Cl
-
mode.
Ca
++
(7.4) will be replaced by Anion Gap in Cl
-
mode