TEMPERATURE COMPENSATION PARAMETERS (P660 to P664)
P660 TEMP SOURCE
This feature is preset to "AUTO". On scanning a transducer, the DPL+ scans the TS-3
temperature sensor assigned to the transducer. If a TS-3 sensor is not connected, the
temperature measurement from the ultrasonic/temperature transducer is used. If the
transducer used does not have an integral temperature sensor, the Temp Fixed (P661)
value is used.
If the temperature of the atmosphere within the transducer beam varies with distance
from the transducer, connect a TS-3 Temperature Sensor and an ultrasonic/temperature
transducer for the Point Number and select "average".
If the atmosphere temperature of two vessels is identical, connect a TS-3 Temperature
Sensor to terminals 10 and 11 and select "TS-3 SENSOR # 1". The temperature
measurement from the single TS-3 is used for the air temperature measurement
of both vessels.
values: 1 = AUTO
2 = Temp Fixed
3 = Ultrasonic/Temperature Transducer
4 = TS-3 Temperature Sensor
5 = Average
6 = TS-3 SENSOR # 1
P661 TEMP FIXED
Use this feature if a temperature sensing device is not used.
Enter the temperature (in°C) of the vessel atmosphere within the transducer beam. If the
temperature varies with distance from the transducer, enter the average temperature. This
value is preset to 20.00°C.
values: -50 to 150
ENHANCEMENT PARAMETERS