EasyManuals Logo

Mindray A9 Operating Instructions

Mindray A9
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #244 background imageLoading...
Page #244 background image
Accessories
A - 2 Operators Manual of Anesthesia System
WARNING: Please use the accessories specified in this chapter only. Using other
accessories may lead to inaccurate measurements or equipment faults.
WARNING: Disposable accessories must be used only once. Repeated use may lead
to deterioration in performance or cross-infection.
WARNING: Please do not use the accessory if its package or itself is damaged.
WARNING: At the end of its service life, the equipment, as well as its accessories,
must be disposed of in compliance with the guidelines regulating the
disposal of such products, and in accordance with local regulations for
contaminated and biologically hazardous items.
WARNING: Parts which are intended to contact patients must comply with the
biocompatibility requirement of ISO 10993-1 to prevent any adverse
reactions arising from such contact.
TYPE PART NUMBER DESCRIPTION
Vaporizer 801-0631-00076-00 Storage Mount for Vaporizer
AG Accessories 115-051561-00 Multi-gas module with accessory kit (2-slot)
115-058733-00 DRYLINE II Watertrap (adult/pediatric, reusable, 2-slot)
115-058734-00 DRYLINE II Watertrap (neonate, reusable, 2-slot)
115-043017-00 Sampling line (adult/pediatric, disposable)
115-043018-00 Sampling line (neonate, disposable)
115-043020-00 Airway adapter (straight, disposable)
115-043021-00 Airway adapter (elbow, disposable)
CO2 Absorbent
Canister
0683-00-0326-12 CO
2
Absorbent, Pre-Pak (12)
Gas Cylinder
Accessories
0348-00-0185 Washer, Seal for Cylinder
115-033063-00 Cylinder wrench assembly

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA