EasyManuals Logo

Mindray A9 Operating Instructions

Mindray A9
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Symbols Safety
1 - 14 Operator’s Manual of Anesthesia System
Identifier:
manufacturer’s
reference/catalog
number
Identifier: serial
number
IPX1
Protection level of
anesthesia system
against splashing water
Applied parts of
defibrillator proof type
BF equipment
Identifier: Manufacturer
Refer to instruction
manual/booklet
MR Unsafe - keep away from magnetic resonance imaging (MRI) equipment
Conforms to AAMI Std. ES 60601-1, IEC Std.60601- 1-6, IEC Std.60601- 1-8, ISO
Std. 80601-2-13, ISO Std. 80601-2-55.
Certified to CSA Std. C22.2 NO. 60601-1, NO.60601-1-6, NO.60601-1-8, NO.60601-
2-10, NO.80601-2-13, NO.60601-2-26, NO.80601-2-55.
E
Electrical:
WEEE (Waste of Electrical and Electronic Equipment) Marking. Separate
treatment from general waste at end of life.
Rx Only
U.S. Federal Law restricts this device to sale by or on the order of a physician or
other practitioner licensed by state law to use or order the use of this device.
Battery is fully charged. AC power
is connected and it is powering
the system.
Alarm Audio Off icon
Battery is partially charged. AC
power is connected. It is charging
the battery and powering the
system.
Alarm Audio Pause icon
Battery is fully charged and it is
powering the system. AC power
is not connected.
Alarm Off icon
Battery is partially charged and it
is powering the system. AC
power is not connected.
Low priority message
3179617

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA