Example
The command character for output is “P” (“output to Port”). To trigger this command, send the string: “ESC P CR LF”.
Command Meaning
K Weighing mode 1
L Weighing mode 2
M Weighing mode 3
N Weighing mode 4
O Block keys
P Send display value to data interface
Q Output acoustic signal
R Unblock keys
T Tare and zero
(combination tare function)
f3_ Zero (see also the “kZE_” command)
f4_ Tare without zeroing (see also the “kT_” command)
i_ Information about the indicator, example of output: “CAIS3/01-63-09/1”
Meaning: Indicator: Combics 3, software version: 01-63-02,
Active weighing platform: 1
kF1_ Trigger soft key F1 function
kF2_ Trigger soft key F2 function
kF3_ Trigger soft key F3 function
kF4_ Trigger soft key F4 function
kF5_ Trigger soft key F5 function
kF6_ Trigger R key function
kF7_ Trigger H key function
kF8_ Trigger D key function
kF9_ Trigger k key function
kF10_ Trigger J key function
kF11_ Trigger K key function
kF12_ Trigger L key function
kP_ Trigger p key function (print at printer interface)
a6_ Alibi memory: next stable weighing value is written to alibi memory and sent back
a7_ Write a stable weighing value previously requested by ESC to the alibi memory when SBI output mode 6.1.8 is active.
The transaction number is returned. Only effective with setting Protocol printout without stability (6.1.8)
a4xx_ Alibi memory: Read content according to the transaction number specied under xx
kT_ Trigger ) key (tare)
kNW_ Trigger n key function (toggle the weighing platform)
kZE_ Trigger ( key function (zero the instrument)
kCF_ Trigger c key function
x1_ Output model designation of active weighing platform, example: “LP6200S-0C”
x2_ Output serial number of active weighing platform, example: “0012345678”
x3_ Output software version of active weighing platform, example: “00-43-04”
x4_ Output software version of indicator, example: “01-63-09”
x9_ Output serial number of indicator, example: “0012345678”
x10_ Output model of indicator, example: “CAIS3”
x12_ Output Max load of the current scale
x13_ Output Min load of the current scale
x14_ Output Max load of the current weighing range of the current scale
x15_ Output Min load of the current weighing range of the current
scalez1xx_ Input: printout header 1
z2xx_ Input: printout header 2
z3xx_ - z8xx_ Input: ID1 - 6
txx…x_ Write text in display. xx…x is the text to be displayed.
The ASCII code for the “underline” character (“_”) is 95.
Format for entering printout header lines: “ESC z x a ... a _ CR LF” with x=1 or 2 and
a ... a: 1 to 20 characters for header x, followed by the underline, CR and LF characters.
Operating Instructions Combics Complete Scales 101
Data Interfaces

Table of Contents

Related product manuals