Care and Maintenance
Service
Regular servicing by a Minebea Intec technician will extend the service life of
your device and ensure its continued weighing accuracy. Minebea Intec oers its
customers service contracts with regular maintenance intervals ranging from one
month to two years. The frequency of the maintenance intervals depends on the
operating conditions and the operator‘s tolerance requirements.
Repairs
2
Disconnect the power supply to the defective equipment immediately (unplug the
power cord from the mains supply). Repair work must be performed by authorized
Minebea Intec service technicians using original spare parts. Repairs performed by
untrained persons may result in considerable hazards for the user.
2
If a cable or cable gland is damaged or defective, replace the cable as a complete
unit with all its connectors.
2
Do not open the indicator while it is carrying current. Wait at least 10 seconds after
disconnecting it from power before beginning to open the equipment. Proper tting
of all surfaces is essential for the IP rating of the housing; for this reason the device
must be opened and closed by a certied technician.
Cleaning
2
Disconnect the power supply to the scale before cleaning (unplug the power cord
from the mains supply).
Cleaning the interior of the weighing platform (CAW.. models only)
t Remove the load plate. Special care is required for models larger than 1000 x
1000 mm.
t Use compressed air to clean out the interior or use a weak water jet (max. 60°C).
Take special care that no dirt gets into the gap of the overload protection
(gap between the load sensor and screw-on plate).
Corrosive Environment
t Remove all traces of corrosive substances from the device on a regular basis.
Cleaning the Indicator
2
Disconnect the power supply to the indicator (unplug the power cord from the
mains supply). If necessary, disconnect the data cable.
2
Make sure that no liquid enters the indicator.
2
Do not use aggressive cleaning agents (solvents or similar agents).
2
Do not spray the device with water or blow with compressed air.
Operating Instructions Combics Complete Scales 117
Care and Maintenance

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec CAS-SPC Series and is the answer not in the manual?

Minebea Intec CAS-SPC Series Specifications

General IconGeneral
BrandMinebea Intec
ModelCAS-SPC Series
CategoryScales
LanguageEnglish

Related product manuals