5.7.6 STMR (FNC 65)
Operation:
The designated timer Swill operate for the duration
n with the operational effect being flagged by
devices D+0to D+3. Device D+0is an off-delay
timer, D+1is a one shot timer. When D+3 is used in
the configuration below, D+1and D+2act in a
alternate flashing sequence.
Mnemonic Function
Operands
Program steps
SnD
STMR
FNC 65
(Special
timer)
Provides
dedicated
off-delay, one
shot and flash
timers
T
Note:
Timers0to199
(100msec
devices)
K, H
)
Note:
n=
1to32,767
Y, M, S
Note:uses 4
consecutive
devices
D+0to D+3
STMR:
7steps
FX
1S
FX
1N
FX
2N
FX
2NC
PULSE-P
16 BIT OPERATION
32 BIT OPERATION
X0
K 100 M 0
[ S ]
[ D ]
T 10STMR
[ n ]
X0
M0
M1
M2
M3
X0
K 100 M 0T 10STMR
M3
X0
M2
M1(M3)

Table of Contents

Other manuals for Mitsubishi FX1N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX1N Series and is the answer not in the manual?

Mitsubishi FX1N Series Specifications

General IconGeneral
Programming LanguageLadder Logic
Output TypeRelay, Transistor
Operating Temperature0 to 55°C
Power Supply100-240V AC or 24V DC
Program Capacity8K steps
Communication PortsRS-422
Data Memory8000 words
High-speed CountersUp to 6 channels
Expansion ModulesAvailable
Pulse Output2 points

Related product manuals