FX Series Programmable Controllers Assigning System Devices 9
9-3
X00
M8015
M0
K30
D8013
MOV
K20
D8014
MOV
K10
D8015
MOV
K25
D8016
MOV
K4
D8017
MOV
K96
D8018
MOV
K4
D8019
MOV
M8017
X1
M0
PLF
The clock stops when X0 is ON.
The new values are set when X0 turns OFF.
X1 is used to reset the clock
to the nearest minute.
These devices are used as shown in the program on
the right.
Note: The FX
2N and FX2NC has special instructions
that simplify the setting and use of the RTC.
See section 5.14 for more details.