55
FX3UC Series Programmable Controllers
User’s Manual - Hardware Edition
1 Outline
1.10 Restriction in number of units in each group
1
Outline
2
External
Dimensions
3
Generic
Specifications
4
Power Supply
Specifications
5
Input
Specifications
6
Output
Specifications
7
Examples of
Wiring for
Various Uses
8
Terminal Block
9
CC-Link/LT
Master FX
3UC
(LT only)
10
Display module
FX
3UC
(LT only)
I/O extension devices
Special function devices
- Special function units
- Special function blocks
In addition to the restrictions shown on the previous page, the number of units
connectable to the main unit or extension power supply unit is restricted in the
following models.
*1. When the FX
0N-3A, FX2N-2AD or FX2N-2DA is used, up to 4 units in total can
be connected. When the FX
0N-3A, FX2N-2AD or FX2N-2DA is not used, up to
5 units in total can be connected.
*2. Consider the restriction for the number of special function equipment.
Note that the number of connectable units is restricted for the following special
function units/blocks.
Division Contents of restrictions
C
D
Model name
Connection target and number of connectable units
FX3UC-MT/D
FX3UC-1PS-5V
FX
2NC-16EYR-T
When the FX
2NC-16EYR-T is
not used, up to 4 units in total
can be connected.
When the FX
2NC-16EYR-T is
used, refer to the note
*1
below.
Up to 5 units in total can
be connected.
FX
2N-8ER
FX
2N-8EYR
FX
2N-8EYT
FX
2N-8EYT-H
FX
2N-16EYR
FX
0N-3A
*2
FX2N-2AD
*2
FX2N-2DA
*2
AA
E
Model name
Connection target and number of connectable units
FX3UC-MT/DSS
FX3UC-1PS-5V
FX
2NC-16EYR-T-DS
When the FX
2NC-16EYR-T-
DS is not used, up to 4 units
in total can be connected.
When the FX
2NC-16EYR-T-
DS is used, refer to the note
*1
below.
Up to 5 units in total can
be connected.
FX
2N-8ER-ES/UL
FX
2N-8EYR-ES/UL
FX
2N-8EYT-ESS/UL
FX
2N-16EYR-ES/UL
FX
0N-3A
*2
FX2N-2AD
*2
FX2N-2DA
*2
AA
E
Model name Restrictions
FX
2N-16CCL-M
It cannot be used together with the FX
2N-32ASI-M.
- When some units are used, a remote I/O station
cannot be connected to the second or following
master stations.
FX
2N-32ASI-M
It cannot be used together with the FX
2N-16CCL-M.
- Only one unit can be used for the whole system.
FX
2N-1RM-SET
FX
2N-1RM-E-
SET
Up to 3 units can be sequentially connected to the end of a
system. However, when three units are connected, they are
counted as one unit, and the number of input/output
occupied points is 8.

Table of Contents

Other manuals for Mitsubishi FX3UC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3UC Series and is the answer not in the manual?

Mitsubishi FX3UC Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3UC Series
CategoryController
LanguageEnglish

Related product manuals