Tank Operation
Manually open the primary shut-off
valve located on the LP-Gas tank.
Turn off the primary valve on the LP-
Gas tank when the tank is being  lled,
when driving, in between trips and when
in storage.
Hand-tighten the primary valve only.
DO NOT use a wrench or pliers. This
will over-tighten the valve. The primary
valve is designed to be closed by hand.
Over-tightening may permanently
damage the valve seat.
NOTE:
In some states and Canadian provinces,
it may be illegal to drive the motorhome
while primary valve on the LP-Gas tank
is open.
Accessory Hookup
Exterior Gas Line Hookup Prep:
An auxiliary remote LP-Gas
hookup is for external LP-Gas
accessories only. For safety, only
approved LP-Gas quick disconnect
ttings and  exible hose should be
used to connect external accessories
to the remote hookup. A LP-Gas
quick disconnect  tting should
be installed by a quali ed agency
as de ned in the National Fire
Protection Association NFPA (Fire)
54-02 code.
NOTE:
Check for leaks on all
connections each time the
remote hook-up is used. If a
leak is detected, turn off the
primary valve at the main LP-
Gas tank. Contact a qualified
service center for the necessary
repairs.
LP-GAS FUNDAMENTALS
050276
Located in the
Roadside bay.
The above capacities allow for 20% vapor space on each cylinder.
Data taken from the National Fire Prevention Association (NFPA).
Pamphlet #58-1998.
#Capacity
Gallon
Capacity
BTU Capacity
5 1.18 107,909
10 2.36 215,807
11 2.59 237,387
20 4.72 431,613
30 7.08 647,420
40 9.43 863,226
020155b
Located in Roadside Bay
050250d

Table of Contents