APPLIANCES - 4
CAY M A N 2 0 0 7
91
1. Turn Off the water heater.
2. Turn Off the incoming water supply.
3. Open the hot water faucet closest to the
water heater.
4. Open the handle of the P & T valve.
5. Allow excess water to drain from the
water heater through the P & T valve.
When draining is complete, close the P
& T valve by allowing it to snap shut.
Close the faucet and turn on the water
supply.
6. Turn on the water heater.
Burner Compartment:
Periodically inspect the burner compartment
and door screen for foreign material that can
prevent the  ow of combustion and ventilating
air.
CAUTION:
DO NOT block
any opening.
Tips:
Turn off the water
heater when not
in use to conserve
energy.
Shut the water off when not rinsing.
Operate the water heater using LP-Gas
when hooked to 30 Amp shore power.
This will reduce the likelihood of
tripping the shore power breaker. When
the water heater element is in operation,
it will use approximately 12 Amps at 120
Volts AC. Appliances that operate from
120 Volts AC may need to be operated in
sequence to avoid tripping a breaker.
Draining & Storage:
Drain the water heater to prevent freeze
damage if the motorhome is to be stored during
the winter months.
1. Turn off electrical power to the water
heater.
2. Shut off the primary LP-Gas valve.
3. Open low point drains.
4. Open both Hot and Cold on all faucets.
5. Remove water heater drain plug.
6. Turn the bypass valve to the bypass
position.
NOTE:
Be sure to refill the water heater with
water before resuming operation.
Troubleshooting:
Check the burner tube for obstructions
if the water heater fails to light. Insects
may make nests in the burner tube. It is
recommended to clean the burner tube
with a brush and not compressed air.
Compressed air may not fully remove
the obstruction.
If the indicator light on the switch does
not light and the water heater does not
light, ensure interior house power is on
or check for a blown fuse in the house
distribution panel.
If the water heater fails to operate after
checking the fuses, the high-temperature
safety limit switch may be tripped. Have
a quali ed technician inspect the water
heater.
WASHER-DRYER PREPARED (OPTIONAL)
The washer-dryer “prep” package includes
the following items:
1. Color coded water supply lines: red for
hot and blue for cold.
2. A 1½" waste water drain line with
threaded cap, P-trap, and an automatic
vent cap. This will drain the waste
water into the grey water holding tank.
3. A 120 AC Volt receptacle located in the
compartment.
NOTE:
Sidewall dryer vents are not part of the
prep package. If a sidewall vent is to be
installed, properly seal vent to sidewall.
010720e
040495d