Chapter 8
Radio Leak Test
This section discusses radio immersibility concerns, tests, and disassembly and reassembly of the
radios.
8.1
Vacuum Leak Test
The vacuum leak test is performed to ensure that the radio is IPx8 compliant. Perform this test after
servicing the radio and before returning the radio to the customer.
The following parts are required to perform a vacuum leak test:
Vacuum Leak Tester
The Vacuum Leak Tester comes with a gauge and a vacuum hose. A connector with an O-ring, which
must be ordered separately, connects the vacuum hose to the radio leak test fixture. Purchase the
Vacuum Leak Tester from the following supplier:
Supplier:
Horizon Land Malaysia Sdn. Bhd.
Website:
www.horizon-land.com
Contact:
+604-6463636
Model Description:
Horizon Land Delta Version TC-2000
Other items required for the test include:
Table 27: Other Vacuum Leak Test Parts
Part Number Description
66007071001 Vacuum Leak Tester Connector
32007073001 Vacuum Leak Tester Connector O-ring
LB001049A01 Ventilation Label
3286058L01 GORE
®
Membrane
Leak Test Fixture
A Leak Test Fixture is also required for the vacuum leak test. Purchase the Leak Test Fixture from the
following supplier:
Supplier:
Access Hitech
Website:
http://www.accesshitech.com
Motorola Solutions Part Number:
TE000060A01
MN006362A01-AL