At Level 1 maintenance, you replace the terminal and/or accessories and send the faulty unified
chassis and/or accessories to a higher level of maintenance. At Level 2 maintenance, a faulty kit is
replaced.
5.5
Protection of Static-Sensitive Devices
This unit contains static-sensitive devices. Static-sensitive devices must be protected in the following
conditions:
When you are opening the unit.
When storing any printed circuit board.
When transporting any printed circuit board.
Create a Proper Ground
Ground the working surface of your service bench. If possible, use the Motorola Solutions Static
Protection Assembly (Part Number: 0180386A82) to ground your service bench. This assembly
contains a wrist strap, two ground cords, a table mat, and a floor mat.
Wear a conductive wrist strap in series with a 1M ohm resistor to ground.
Do not wear nylon clothing when handling any printed-circuit board.
Before touching any printed-circuit board, touch an electrical ground to remove any static charge
that might have accumulated.
Store or Transport a Circuit Board
Place the printed-circuit board in conductive, anti-static material.
Do not insert the printed-circuit board into conventional plastic “snow” trays used for transporting
other devices.