USER MANUAL NOVAplus
MRU GmbH, D-74172 Neckarsulm 1 / 95

Table of Contents

Questions and Answers:

mru NOVAplus Specifications

General IconGeneral
Gas TypesO2, CO, NO, NO2, SO2, H2S, CO2, CxHy
InterfaceUSB, Bluetooth
O2 Measurement Range0-25%
CO2 Measurement Range0-20%
DisplayGraphic LCD
Power SupplyRechargeable battery
Measurement RangeDepends on gas type
ResolutionDependent on sensor and range, see datasheet
Operating Humidity0-95% RH non-condensing

Summary

Product and Safety Information

Safety Manual Overview

Details on general safety precautions and information for MRU products.

Safety Precautions Explained

Explanation of safety precaution categories: DANGER, WARNING, CAUTION, ATTENTION, NOTE.

Ensuring Safe Analyzer Operation

Guidelines for safe use, maintenance, and handling of the analyzer and its components.

General Information EN 50379 and VDI 4206

Important information regarding standards, analyzer setup time, and sensor lifespan.

Rechargeable Battery Guidelines

Instructions for safe handling and use of the internal lithium-ion rechargeable battery.

Introduction to the NOVAplus Analyzer

Intended Use of the Analyzer

Describes the primary applications and optional accessories for the gas analyzer.

About MRU GmbH

Information about the manufacturer, MRU GmbH, and their emission monitoring systems.

Packaging and Material Return

Guidance on saving packaging and procedures for returning hazardous materials and equipment.

Analyzer Description and Principles

Measurement Principle

Explanation of the gas sampling and analysis process using electrochemical sensors.

Operating the NOVAplus Analyzer

Display Information and Indicators

Details on the analyzer's display panel, menu bar, and status indicators.

RCU and Base Unit Keypad Functions

Description and function of each key on the remote control unit and base unit.

Connecting Remote Control Unit (RCU)

Step-by-step guide for establishing a Bluetooth connection between the RCU and base unit.

Reset Procedures and Blink Codes

Instructions for resetting the RCU and base unit, and interpreting LED status codes.

Analyzer Menu Structure Overview

Overview of the three main menus: Measurement, Storage, and Extra.

First Time Analyzer Setup and Configuration

Preparatory Steps Before First Use

Initial steps including unpacking, reading the manual, and charging the battery.

Configuring Analyzer Settings

Adjusting instrument parameters like LCD brightness, country, and language.

Measurement Settings Configuration

Customizing gas cooler mode, probe heating, units, and measurement options.

Switch-On Protection and Print-out Settings

Setting up analyzer startup protection and configuring printout options like logo and site lines.

Bluetooth and Date/Time Configuration

Setting up Bluetooth communication and adjusting the device's date and time.

Configuring Measurement Programs and CO Limit

Setting up measurement programs, fuel types, and adjusting the CO sensor protection limit.

Selecting Fuel Types and O2 Reference

Choosing fuel types for measurements and setting the O2 reference value.

Defining Custom User Fuel Types

Procedure for defining new fuel types and their parameters for personalized measurements.

Defining Measurement and Zoom Windows

Customizing displayed measurement values and zoom window content.

Changing Measurement Program Names

How to rename measurement programs to suit specific user needs.

Measurement Preparation Procedures

Ensuring Power Supply and Auto-Off

Details on using battery or mains power and the automatic shutdown function.

Battery Charge Status and Operation

Understanding battery indicators and charging procedures for base and remote units.

Operating Temperature and Condensate Control

Managing operating temperature issues and controlling the condensate separator.

Connections, Tightness, and Zero-Point Setting

Checking connections, system tightness, and performing automatic zero-point calibration.

Repeating Zeroing and NDIR Bench Calibration

Instructions for repeating the zeroing process and calibrating the 3-gas NDIR bench.

Performing Gas Measurements

Selecting the Appropriate Measuring Program

Guide to choosing and starting measurement programs, including safety warnings.

Core Flow Search for Optimal Measurement

Technique for finding the optimal measurement point in the stack based on temperature.

Interpreting Measured Value Displays

Understanding how measurement values are displayed and organized on the analyzer.

Optional CO Purging and High CO Measurement

Features for CO sensor protection and handling high CO concentrations.

Specific Measurement Applications

Details on 30-sec average value calculation, annular-gap tests, and test programs.

Performing Ambient CO Tests

Procedure for measuring ambient CO concentration, including zeroing and peak values.

Using the Temporary Buffer for Measurements

Storing and managing momentary measurement values in a temporary buffer.

Storing and Overwriting Measurement Data

Saving measurements to memory, overwriting buffer values, and printing soot data.

Printing and Terminating Measurements

How to print measurement results and stop the current measurement.

Accessing Last Measured Values

Retrieving and continuing work with the last recorded measurement values.

Pressure Measurement Procedures

Measuring and saving pressure values, and rearranging differential pressure sensors.

Differential Temperature Measurement

Displaying and calculating differential temperatures using connected sensors.

Data Storage and Management

Organizing and Calling Up Data Storage

Managing sites, viewing memory information, and understanding data storage structure.

Site Administration: Creating and Managing Sites

Creating, viewing, searching, changing, and deleting sites within the analyzer's memory.

Importing Sites from SD Card

Procedure for importing site data from a computer or another analyzer via SD card.

Exporting Sites to SD Card

Saving analyzer site data to an SD card for backup or transfer.

Exporting Combustion Measurements

Exporting measurement data for combustion analysis to a computer program.

Exporting Differential Pressure Measurements

Exporting differential pressure measurement data in CSV format.

Viewing and Deleting Measurements

Inspecting stored measurements and deleting specific measurement types.

Data Transfer to PC via USB

Connecting the analyzer to a PC for data transfer using the MRU-ZIV module.

Analyzer Extras and Adjustments

User Definable Logo Printout

Customizing printouts by adding a user-defined logo created from a bitmap file.

Service Calibration Menu Access

Accessing the maintenance and adjustment menu, protected by a PIN code.

Resetting to Default Settings

Restoring the analyzer to its original factory settings, cautioning about data loss.

Accessing Service Values (RCU/Base Unit)

Viewing service values for sensors and parameters to diagnose potential defects.

Performing Leak Proof Tests

Procedure for checking the system's tightness using a leak proof test cap.

Viewing SD Card Contents

Accessing and managing files stored on the SD card.

Analyzer and Option Information

Displaying information about the analyzer hardware, firmware, and installed options.

Performing Self Diagnostics

Running self-diagnostic tests to check the condition of batteries, sensors, and flow control.

Analyzer Maintenance and Care

Cleaning Procedures for Probe and Hose

Routine cleaning of the probe, probe hose, and ensuring proper drying after use.

Scheduled Maintenance and Sensor Adjustment

Recommendations for annual service checks and sensor calibration frequency.

Understanding Service Messages

Information on service reminders and what a complete service includes.

Appendix: Technical Data and Calculations

General Technical Data

Specifications for operating temperature, humidity, storage, power, and physical dimensions.

Gas Sampling and Conditioning Details

Information on condensate traps, gas coolers, and humidity alarms.

Measurement Accuracy Data

Details on sensor accuracy, resolution, response times, and expected lifespan.

Calculated Measurement Values

Explanation of calculated values like CO2, efficiency, losses, and dew point.

Analysis and Calculation Methods

Overview of measured values and available conversions, including efficiency and loss calculations.

Fuel Type Lists for Calculations

Lists of fuel types with corresponding CO2max, O2max, and other parameters for German and Austrian fuels.

Text Input and User Decision Functions

How to input text for names and settings, and how the analyzer asks for user confirmation.

Firmware Update Procedure

Step-by-step guide for updating the analyzer's firmware using an SD card.

Troubleshooting Common Analyzer Issues

Guide to diagnosing and resolving issues like device not reacting or incorrect measurements.

Declaration of Conformity

Related product manuals