7.6 Faults
WARNING!
If the device is in critical fault mode, the device will not be monitoring for gas.
Failure to follow these warnings can result in serious bodily injury or death.
There are two types of faults: noncritical and critical.
Alarm events have priority over fault events. If a point has an alarm during a fault event, the point tile
on the dashboard shows in red to indicate the alarm, not in yellow to indicate the fault.
7.6.1 Noncritical Faults
Faults can be acknowledged and reset through the pop-up
if it is a channel related fault.
If the fault is system related, it is acknowledged and reset
through the fault tab in the event log. Once the reset is initi-
ated on the system related faults, it will reset all of the faults
concurrently.
For faults related to the display, the system will notify the
user upon reset.
When a noncritical fault occurs, a pop-up with a yellow
background signals the event on the dashboard.
If multiple faults occur simultaneously, the pop-up shows
the faults as line items.
To acknowledge the event and return to the dashboard,
select "Acknowledge".
If the fault can be related to a single or multiple points, the
associated point tiles show on the dashboard with a yellow
background.