10.06.2014 125
Gas flushing
[Optional]
The film pouches are filled with inert gas.
Gas flushing with inert gas has the following advantages:
It extends the shelf life of the product.
It reduces oxygen content.
It avoids putting pressure on the product.
Gas flushing pressure
[Optional] [Parameter of the control unit]
Indicates the pressure up to which the film pouch is back filled with
inert gas. Pressure is measured in the chamber.
Gas flushing time
[Optional] [Parameter of the control unit]
Indicates the amount of time for which the film pouch will be filled
with inert gas. The pressure can not be influenced by this.
Hours of operation
[Parameter of the control unit]
Shows the time the machine has been operating. The counter be-
gins to count as soon as the machine is switched on and can not be
reset.
Instructed person
An instructed person is someone who has been instructed and
trained in regard to the potential hazards of his or her assigned
tasks, as well as in regard to the necessary safety devices, protec-
tive measures, relevant stipulations, accident prevention regulations
and operating conditions, and whose competence has been demon-
strated.