Technical specifications
10.06.2014 43
Installation conditions and ambient conditions
Minimum room size for machines
with the gas flushing option*
40 m
2
*For safety reasons, a minimum room size is mandatory to prevent
high concentrations of gas.
Inert gas without gas mixer (option)
Max. input pressure 2.5 bar
Min. input pressure 0.7 bar
Sealing operating pressure 1.0 bar
Inner diameter of supply line 8 mm
Inert gas with gas mixer (option)
Maximum CO
2
input pressure 2.5 bar
Minimum CO
2
input pressure 1.0 bar
Maximum N
2
input pressure 3.5 bar
Minimum N
2
input pressure 2.0 bar
Sealing operating pressure 1.0 bar
Inner diameter of supply line 6 mm
Vacuum pump
Nominal suction capacity R5-xxx
• 40 m
3
/h
• 63 m
3
/h
Nominal suction capacity MRP60
50 Hz: 60 m
3
/h
60 Hz: 75 m
3
/h
Achievable final pressure approx. 2 mbar
Noise exposure at the workplace
Based on Machinery Directive
(2006/42/EC)
Measuring instrument Sound level meter, IEC 61672- 1,
class 1, error limit +/-1.1 dB
Condition of the machine New condition with optimum set-
tings at the time of delivery.