Cleaning
Cleaning the machine
78 10.06.2014
NOTICE Danger of material damage!
The Teflon tape of the sealing bar is very sensitive.
Improper cleaning can damage the Teflon tape.
¾ Clean the Teflon tape only with a soft cloth.
¾ Do NOT scratch the Teflon tape.
¾ Manually clean the removed components.
¾ Thoroughly clean the inert gas nozzles.
¾ Perform a quick disinfection of the removed components.
¾ Thoroughly disinfect the inert gas nozzles.
Disinfect and cover
sensitive components
¾ If the external vacuum pump is connected directly to the mains
electricity, have the external vacuum pump disconnected from the
mains electricity by a qualified electrician.
¾ Cover the mains plug with waterproof plastic bags.
WARNING
Burn hazard!
The surface of the vacuum pump can reach temperatures of over
70 °C during operation.
Touching the vacuum pump can lead to burns.
Before performing any work on the vacuum pump:
¾ Allow the vacuum pump to cool down.
¾ Wear personal protective equipment.
¾ Perform a quick disinfection of the following components: If there
is visible contamination carry out a prior manual cleaning:
– External vacuum pump.
¾ Cover disinfected components with watertight film pouches.