Section 75 00-02-0878
2013-03-07 - 89 -
RMI Fuel
This RMI input is used for the fuel level sensor.
RMI Sensor Type
Type 1
Value Resistance
0% 78.8 Ω
100% 1.6 Ω
RMI Sensor Type
Type 2
Value Resistance
0% 3 Ω
100% 180 Ω
NOTE: If the RMI input is used as a level switch, then be aware
that no voltage must be connected to the input. If any voltage is
applied to the RMI inputs, it will be damaged. Please refer to the
Application Notes for further wiring information.
RMI sensor type
Value Type configurable
% Resistance
0
10
20
30
40
50
60
70
80
90
100
NOTE: The configurable type is configurable with eight points in
the range 0-480 Ω. The value as well as the resistance can be
adjusted.