6.3 Entering Configuration Settings from the GT30 Main Unit
6.3.5 Setting Mode: “Communication Parameters”
(TOOL Port / COM. Port)
Touch the [Port] key on the initial screen of the system menu to display the
communication parameters setting screen. Here, parameters controlling
communication between the PLC and personal computer (GTWIN) connected to the
GT30 are specified.
Port communication parameter settings
Procedure for bringingup thescreen
[Initial screen]
[Port]
↓
TOOL Port communication parameter settings (GTWIN communication parameter
settings)
Through function: Through function destination setting
When the through function is being used, this specifies the number of the PLC at the
other end of the connection. Normally, when used in a 1 : 1 configuration, this should
be set to “00”.
Bitrate: GTWIN communication speed
Each time the [Function] key is touched, the Baud rate switches in the sequence of
9600/19200/115200 bits/s. Set the speed to match that of the personal computer
(GTWIN) connected to the GT30.
Format: Transmission format
Thissets the communication parameters (data length, stop bits, parity) for the personal
computer (GTWIN) connected to the GT30.
Theitemsdisplayed are: Data length/ Stopbit / Parity, andeach time the [Function] key
is pressed, the display switches in the sequence of: [8/1/None], [8/1/Odd], [8/1/Even].