CHAPTER 2 INSTALLATION
– 72 –
NWA-008855-001 Rev.1.0
avch2001.fm
(d) Set IP Address of DRS and port number
NOTE: The IP-CS is registered to the MP built-in DRS which makes the IP-CS a subordinate. Set the
IP Address of Primary DRS as follows.
When IP-CS is accommodated in a Main Site of Remote PIM over IP or Remote PIM over
IP is not provided, set the IP Address of MP by CM0B Y=00>00.
When IP-CS is accommodated in a Remote Site of Remote PIM over IP, set the IP Address of
MP for the Remote Site by CM0B Y=31-60>00.
<IP Address of Primary DRS>
Command: set drspip
Example:
IP Address of Primary DRS : 10.41.207.30.
The “set done” message is indicated when the IP-CS has received the assigned data normally.
Assigned data can be read by entering “show drspip” command.
<DRS Port Number>
NOTE: Set DRS port number for the setting data by CM0B Y=10>60 (default data is 3456).
Command: set drsudp
Example:
DRS port number: 3457
The “set done” message is indicated when the IP-CS has received the assigned data normally.
Assigned data can be read by entering “show drsudp” command.
>set drspip 10.41.207.30
>set drsudp 3457
SETUP OF IP-CS