SELECTOR
Dosing
Prog.
S1 S2 S3 S4 S5
1
2
3
4
5
· · · ·
· · · ·
· · · ·
· · · ·
· · · ·
Assign Selector to a Fertilizer Program using the +/- keys.
1.7 FILTER FLUSHING
Enables to define the required process for filter flushing.
Notice that there are a few steps that should be defined prior to this screen:
Table
6.1 SYSTEM SETUP
Stop irrigation during filter flushing - yes/no
Stop fertilizing during filter flushing - yes/no
FILTER FLUSHING PROGRAM
Time Between Flush (hh:mm)
Flushing (mm:ss)
Delay (mm:ss)
Delta Pressure
Delay Delta Pressure (sec.)
Delta Pressure Reiteration
Dwell Time Main Filter (s)
06:00
01:00
00:30
YES
6
3
0
Time Between Flushing (hh:mm) - Time interval between two consecutive Flushing
cycles. The time is only counted during irrigation.
Example: If time between flushing is set to 01:00 it means that after 1 hour of
irrigation a flushing cycle will be activated.
Flushing Time (mm:ss) – Flushing time of each Filter (output).
Delay Between Filters (mm:ss) - The delay time between flushing of one filter to
the next. This time is usually used to enable buildup of pressure.