NMC-64 Irrigation
Analog Input Card:
• If only one card is present it will always be number 1, regardless of its position.
• When add a card to a system that already has one Analog input card, the new card
will be number 2 regardless of its position.
• Two cards installed in the system (After Cold Start), are numbered from right to
left.
Digital Input Card:
• Cards numbering is according to the jumpers setting on the cards.
Jum
ers 3-4 are not in use
• If you add a new card with an identical number to one already in, the controller
sends a message of a numbering conflict and will disregard the new card. Turn off
the power and change the new card’s number (Jumper).
• If after Cold Start there are 2 cards with identical numbers, the controller will
recognize the right-sided one and will ignore the left one. Turn off the power and
change the jumper position on the left-sided card.