VBA14001-R.3694.A
- R4
・
-
Q0340グラフィック用ロゴ
060411デザイン部伊藤
Items Judgment standard Remarks
Standby / consumed
current
Main SW / OFF: 250μA or less
(Do NOT press any operational buttons.)
Main SW / ON (Half-release timer: OFF): 250μA or less
Main SW / ON (Half-release timer: ON): 250μA or less
Main SW / ON (Illumination: ON): 300μA or less
Main SW / ON (TFT ON): 1A or less
Constant-voltage
power source (5A or
more)
Battery tool
(J61213)
Ammeter
AF50/1.4
EV12
Operation time /
consumption current
accumulated
Lens scan
AF50/1.8
Operation time: 1000 ms or less
Consumption current accumulated: 500mAsec or less
AF70-210/4-5.6
Operation time: 2000ms or less
Consumption current accumulated: 800mAsec or less
Preview
Operation time: 200ms or less
Consumption current accumulated: 120mAsec or less
Release without memory card Operation time: 300ms or less
Consumption current accumulated: 250mAsec or less
Constant voltage
power source (5A or
more)
Battery tool
(J61210)
Special tool
Oscilloscope
LV12
Clock accuracy Difference par month: ±30 seconds (20℃) Wave clock
BC level Level 5: 5 lights up Charge remaining: 70 ~ 100%
Level 4: 4 lights up Charge remaining: 50 ~ 69%
Level 3: 3 lights up Charge remaining: 35 ~ 49%
Level 2: 2 lights up Charge remaining: 20 ~ 34%
Level 1:
1 light up Charge remaining: 1 ~ 19%
Level 0: 1 light blinking Charge remaining: 0%
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Bulb battery life When special Li-ion is used: 2 and a half hours or more Clock
Remote wire