EasyManua.ls Logo

Nilfisk-Advance BR 751 - VACUUM SYSTEM MOTOR CARBON BRUSH CHECK and REPLACEMENT (Starting from S;N

Nilfisk-Advance BR 751
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL
ENGLISH
BR 601 / BR 651 / BR 751 / BR 751 C 909 6424 000(3)2007-12
41
RECOVERY WATER SYSTEM
VACUUM SYSTEM MOTOR CARBON BRUSH CHECK AND REPLACEMENT (starting from S/N ..........)
Drive the machine to the appointed disposal area, and empty the recovery water tank (58) with the hose (22).
Empty the solution tank (59) with the tap (36).
Drive the machine on a level fl oor.
Turn the ignition key (12) to "0".
Carefully lift the tank assembly (60) to reach the batteries.
Disconnect the battery connector (63).
Remove the cover (A) from the vacuum system motor (B).
Remove the screws (C).
Disconnect the electrical connections (D).
Remove the carbon brushes (E).
Check the carbon brushes for wear. Replace the carbon brushes when: the contact with the motor armature is insuffi cient, the
carbon brushes are worn, the carbon brush contact surface is not integral, the thrust spring is broken, etc.
If necessary, replace the carbon brushes. Replace the carbon brushes as an assembly.
Assemble the components in the reverse order of disassembly.
S301337
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

Table of Contents