ENGLISH
SERVICE MANUAL
80
909 6424 000(3)2007-12 BR 601 / BR 651 / BR 751 / BR 751 C
ELECTRICAL SYSTEM
FUSE CHECK/REPLACEMENT
Turn the ignition key (12) to "0".
Remove the nuts (93), then remove the cover (92).
Check/replace the following fuse:
Drive system electronic board protection fuse (F2) (60 A) (96)
Carefully move the electronic component panel (100) and check/replace the following fuses:
Low power circuit protection fuse (F3) (5 A) (A)
Function electronic board protection fuse (F1) (100 A) (B)
Install the electrical component panel (100) and the cover (92), then tighten the nuts (93).
(Only for machines with EDS - ECO Dosage Solution) Remove the mounting screws and carefully lift the control panel (1),
then check/replace the following fuse:
Pump fuse (F4) 3.15 A (C)
Install the control panel (1) and tighten the mounting screws.