EasyManua.ls Logo

Nokia 7705 SAR-W Series - Configuring PCC-Controlled, PCE-Computed, and PCE-Controlled SR-TE Lsps

Nokia 7705 SAR-W Series
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPLS and RSVP-TE
152
MPLS Guide
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 18686 AAAB TQZZA
While protection is enabled globally for all node SIDs and local adjacency SIDs when
the user enables the loopfree-alternates option in IS-IS or OSPF at the LER and
LSR, there are applications where the user wants traffic to never divert from the strict
hop computed by CSPF for an SR-TE LSP. In that case, use the following syntax to
disable protection for all adjacency SIDs formed over a particular network IP
interface:
CLI Syntax: config>router>ospf>area>if>no sid-protection
config>router>isis>if>no sid-protection
Example: node-sid index 194
no sid-protection
no shutdown
3.23.6 Configuring PCC-controlled, PCE-computed, and
PCE-controlled SR-TE LSPs
The following example shows the configuration of PCEP PCC parameters on LER
routers that require peering with the PCE server:
Example: keepalive 30
dead-timer 120
no local-address
unknown-message-rate 10
report-path-constraints
peer 192.0.0.226
no shutdown
exit
no shutdown
The following example shows the configuration of a PCC-controlled SR-TE LSP that
is not reported to the PCE:
Example: lsp "to-SanFrancisco" sr-te
to 192.0.2.211
cspf
pce-report disable
metric 10
primary "loose-anycast"
exit
no shutdown
exit