EasyManua.ls Logo

Nokia 7705 SAR-W Series - Modifying Interface Parameters

Nokia 7705 SAR-W Series
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Label Distribution Protocol
442
MPLS Guide
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 18686 AAAB TQZZA
config>router>ldp>targeted# no shutdown
config>router>ldp>targeted# no peer 10.10.10.99
The following example displays the default value output.
ALU-1>config>router>ldp>targeted# info detail
----------------------------------------------
no disable-targeted-session
hello 45 3
keepalive 40 4
----------------------------------------------
ALU-1>config>router>ldp>targeted#
5.11.3 Modifying Interface Parameters
You can modify LDP interface parameters without shutting down entities. However,
at the global timer configuration level (ldp>interface-parameters), the hello and
keepalive parameter modifications do not take effect until a shutdown/no
shutdown command is performed on the LDP session. At the interface timer
configuration level (ldp>interface-parameters>interface), any changes to the
keepalive parameter do not take effect until a shutdown/no shutdown command
is performed on the LDP session. For all other parameters, the changes take effect
immediately.
Individual parameters cannot be deleted. The no form of an interface-parameter
command changes modified values back to the defaults.
The following example displays the CLI syntax to change interface parameters back
to the default values.
Example: config>router# ldp
config>router>ldp>interface-parameters
config>router>ldp>if-params# no hello
config>router>ldp>if-params# interface to-104
config>router>ldp>if-params>if# no keepalive
config>router>ldp>if-params>if# no transport-address
config>router>ldp>if-params>if# shutdown
config>router>ldp>if-params>if# no shutdown
config>router>ldp>if-params>if# exit
config>router>ldp>if-params# exit
config>router>ldp# shutdown
config>router>ldp# no shutdown
The following example displays the default value output.