EasyManuals Logo
Home>nord>Synthesizer>modular G2

nord modular G2 User Manual

nord modular G2
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
NORD MODULAR G2 V1.1 11. Module reference: LFO group
Page 141
1/96
1/96 1/96
1/96
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output transmits 96 clock pulses per note (or 24 clock pulses for each quarter note).
Signal: Logic.
1/16
1/16 1/16
1/16
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output transmits 16 clock pulses per note (or 4 clock pulses for each quarter note).
Signal: Logic.
S
SS
S
Y
YY
YN
NN
NC
CC
C
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output provides you with a logic pulse, which is calculated from the Clock signal, at a rate
set by the ‘Sync every nn beats’ parameter mentioned above. The Sync function provides a method of
telling the Nord Modular G2 sequencer modules where the first beat in a bar is. Patch this output to the
Rst (reset) input of the sequencer modules. This function is absolutely essential to use if you plan to syn-
chronize patches in different slots to each other, or if you want to synchronize Nord Modular G2 to an
external sequencer. Signal: Logic.
• Try to make a habit out of always using this function if you are using more than one sequencer module
in a patch, especially if you want to mix modules clocked with e.g. triplet resolutions with other mod-
ules clocked with eighth or sixteenth notes.
See also "Common LFO parameters”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the nord modular G2 and is the answer not in the manual?

nord modular G2 Specifications

General IconGeneral
Brandnord
Modelmodular G2
CategorySynthesizer
LanguageEnglish