NORD MODULAR G2 V1.1 11. Module reference: LFO group
Page 141
1/96
1/96 1/96
1/96
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output transmits 96 clock pulses per note (or 24 clock pulses for each quarter note).
Signal: Logic.
1/16
1/16 1/16
1/16
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output transmits 16 clock pulses per note (or 4 clock pulses for each quarter note).
Signal: Logic.
S
SS
S
Y
YY
YN
NN
NC
CC
C
O
OO
OU
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
This yellow output provides you with a logic pulse, which is calculated from the Clock signal, at a rate
set by the ‘Sync every nn beats’ parameter mentioned above. The Sync function provides a method of
telling the Nord Modular G2 sequencer modules where the first beat in a bar is. Patch this output to the
Rst (reset) input of the sequencer modules. This function is absolutely essential to use if you plan to syn-
chronize patches in different slots to each other, or if you want to synchronize Nord Modular G2 to an
external sequencer. Signal: Logic.
• Try to make a habit out of always using this function if you are using more than one sequencer module
in a patch, especially if you want to mix modules clocked with e.g. triplet resolutions with other mod-
ules clocked with eighth or sixteenth notes.
See also "Common LFO parameters”.