Spray Gun Preset Settings
5-14
Part 1056418-07
E 2019 Nordson Corporation
Select Charge Mode (contd)
Table 5-5 Select Charge Modes
Select Charge Modes
Mode 0 (Off): Turn Select Charge off to set kV or AFC.
Mode 1 (Recoat): Use this mode for recoating parts that have already been coated and
cured. Gun current is aggressively reduced to eliminate back ionization.
Mode 2 (Special): Use this mode for coating with special powders (dry blend metallics or
micas).
Mode 3 (Deep Cavity): Use this mode for coating inside boxes or other deep cavities. Low
kV and current coats the front edges of the cavity and high kV and current coats the back of
the cavity.
Mode 4 (User Programmable): This mode allows you to set both kV and μA for a particular
part or powder and store the setting. The settings are loaded each time Mode 4 is selected.
Table 5-6 Select Charge Mode Values
Select
Charge
Mode
Application
kV/AFC
Setting
Initial kV Value Max. Current
Prodigy/Encore
HD, Encore,
Sure Coat
Versa-Spray All Guns
1 Recoat not adjustable 95 kV 100 kV 15 μA
2 Special not adjustable 60 kV 60 kV 30 μA
3 Deep Cavity, gun
inside
not adjustable 95 kV 100 kV 70 μA
4 User Programmable adjustable 60 kV 60 kV 30 μA