EasyManua.ls Logo

Nordson iControl Series - Digital Zone Triggering Examples; Gun to Zone Assignments; Zone Triggering with Solid Parts

Nordson iControl Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standard System Configuration
3-9
Part 1056418-07
E 2019 Nordson Corporation
Digital Zone Triggering
See Figure 3-5. In this example, eight zone photoeyes are mounted so that
they create eight vertical zones within the booth. The guns are assigned to
the zones as follows for all three parts:
Gun to Zone Assignments
Guns Zones Guns Zones
1 1 5 2
2 3 6 4
3 5 7 6
4 7 8 8
See Figure 3-5:
Part 1 occupies all 8 zones, so all guns are triggered on.
Part 2 occupies only zones 14 so only the guns assigned to those zones
are triggered on.
Part 3 occupies only zones 58 so only the guns assigned to those zones
are triggered on.
NOTE: Part 3 is hung so that the hangers occupy zones 14. Normally,
this could trigger on the spray guns assigned to those zones. Use Zone
Filtering to prevent spray guns from triggering on hangers. Refer to Zone
Filter Configuration on page 3-11.
Zone 1
Zone 2
Zone 3
Zone 4
Part 1
Part 2
Zone Photoeyes
or Discrete Scanners
Zone 5
Zone 6
Zone 7
Zone 8
Part 3
Spray Guns
8
Powder Spraying
4
1
2
3
5
6
7
8
4
1
2
3
5
6
7
8
4
1
2
3
5
6
7
8
Figure 3-5 Zone Examples with Solid Parts
See Figure 3-6:
As Part 4 moves past the guns, all guns are turned on at the solid sections,
and turned off at the open section. Note that guns 1 and 8 stay on for the
length of the part.