Monitoring Operation
9-2
Part 1056418-07
E 2019 Nordson Corporation
Gun Monitoring
Gun Buttons
The Gun button icons and colors change to indicate the trigger mode and
status of each gun.
Auto: Auto icon appears on the buttons.
The buttons turn light gray when the gun is off; green when
on.
Manual: Manual icon appears on the buttons.
The buttons turn light gray when the gun is off; green when
on.
Off: Gun off icon appears on the buttons.
The buttons turn light gray.
Off Line: Gun off icon appears on the buttons.
The buttons turn blue. Cable is disconnected or exhaust
fan was off when the iControl software loaded.
Off Line: Gun off icon appears on the buttons.
The buttons turn dark gray. Gun controller, iFlow module,
or pump controller not communicating with iControl system.
NOTE: If a gun-related fault occurs, the affected gun button will blink
yellow. If this occurs, touch the button to open the Gun Control screen to
find the fault code. Refer to Alarms in this section for more information.
Global Status Screen
Touching the Global Status button at the top of the Main screen opens the
Global Status screen, which displays the current preset number being
sprayed and the air flow and electrostatic output for up to sixteen guns at a
time.
The legend on the left side of the screen shows the color coding used in the
bar scales and the meaning of the numbers next to the scales.
Scroll the Consoles/Guns with the Up and Down arrows to display the next
16 guns if your system has more than 16. CA is the master console; CB is
the slave console (Prodigy systems do not use slave consoles but still list
guns 17−32 on CB).
If a gun control card, iFlow module, or pump control card goes offline or
stops communicating with the iControl PC, the Network Error Indicator
appears on the screen next to the gun and preset number.
Touching the Global Hourmeter button opens the Global Hourmeter
screen.