Reciprocator Preset Settings
7-6
Part 1056418-07
E 2019 Nordson Corporation
Reciprocator Preset Percent-Adjust Settings
See Figure 7-4. Reciprocator Preset Percent-Adjust settings change the
current spray gun preset flow-rate and atomizing air settings by a
percentage at points above and below the part edges.
NOTE: Percent Adjust is an additive variable. Reciprocator Preset
Percent-Adjust settings are added or subtracted from Reciprocator Stroke
Length Percent Adjust settings, Global Percent-Adjust settings, and
Conveyor Speed Percent-Adjust settings.
For Spray Gun percent adjust setting instructions, refer to Percent Adjust
Functions in Section 8, Operation. Refer also to Section 4,
Positioner/Reciprocator Configuration for Reciprocator Stroke Length
Percent Adjust.
Variable mode: The On/Off Up/Down settings are the distances from the
edge that the Flow-Rate and Atomizing air percent adjust settings are
turned on and off. The On/Off Up/Down settings can be positive or
negative. Positive settings turn the adjustment on BEFORE the part edge
and off AFTER the part edge. Negative settings turn the adjustment on
AFTER the part edge and off BEFORE the part edge.
Fixed mode: The On/Off Up/Down settings are measured from
reciprocator Home and must always be positive.
The Percent-Adjust Flow-Rate and Atomizing air settings are the percent
by which the current setting is changed. These settings can be positive or
negative. Percent adjust can be Enabled or Disabled for each
reciprocator. Touch the field to toggle the status. When enabled an X is
displayed in the field.
Flow-RateOn Up AtomizingOff Down On Down Off Up Enable/Disable
Variable Mode
% On
% Off
% On
% On
% Off
% Off
Fixed Mode
% On
% Off
% On
% On
% Off
% Off
On Down
Off Up
Off Down
On Up
Reciprocator Home (0)