Monitoring Operation
9-13
Part 1056418-07
E 2019 Nordson Corporation
Node Error Codes
Errors 65, 68: Check Ethernet connections. Usually means controller is
unplugged or off.
Errors 66, 67, 69−75: Programming errors. Call Nordson Technical Support.
Errors 129−132: Noise on circuit. Check connections. Check to ensure
Ethernet cables are not parallel to high voltage or VFDs.
Errors 161−164: Programming errors or hardware error. Call Nordson
Technical Support.
Error Code Description
65 I/O error
66 Port open error
67 Already open
68 Connection error
69 Remote closed connection
70 Library error
71 Port already bound
72 Listen failed
73 File descriptors exceeded
74 No permission
75 Port not available
129 Checksum error
130 Frame error
131 Reply error
132 Reply time-out
161 Modbus exception
162 Illegal address
163 Illegal value
164 Slave device failure
CAN Network Status
The CAN network is the iControl internal network. The iControl system
communicates with the gun control cards over the CAN network. The
Prodigy iControl system uses the CAN network to communicate with the
pump control cards and the manual gun controllers.
Touch the CAN Network Status Button to open the CAN Network Status
screen. Nordson service representatives can use this screen to diagnose
problems with the CAN network.