EasyManua.ls Logo

Nordson iControl Series - Positioner Preset Settings; Introduction to Positioner Presets; Positioner Preset Settings Overview

Nordson iControl Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Positioner Preset Settings
6-1
Part 1056418-07
E 2019 Nordson Corporation
Section 6
Positioner Preset Settings
Contents
Introduction 6-1.............................................
Positioner Preset Settings 6-2.................................
Copying Preset Settings 6-3................................
Saving Preset Settings 6-3.................................
Reset to Defaults 6-3......................................
Using Preset Settings 6-4....................................
Fixed Positioning 6-4......................................
Variable Positioning Contouring 6-5........................
Variable Positioning Lancing and Contouring 6-6............
Variable Positioning Lancing into Deep Recesses 6-7........
Introduction
Positioner presets are recipes that contain the move settings for a specific
part. Up to 255 unique presets can be created on each user data card.
Positioner Preset settings are part-specific. If no preset settings have been
made for a part, the system uses the default positioner settings from the
Configuration screen.
NOTE: If you set any preset settings to less than the configured minimum
settings, then the minimum settings override the preset settings.
Refer to Section 5, Positioner/Reciprocator Configuration for more
information on default and minimum settings.
In/Out Positioner Settings:
S lead and lag move points
S gun to part distance (variable)
S gun position (fixed)

Table of Contents