Reciprocator Preset Settings
7-3
Part 1056418-07
E 2019 Nordson Corporation
Preset Selector
Copy Keypad Save
Reciprocator
Selector
Not Modified
Scroll
Bar
Default Settings
Reciprocators
and Modes
Modified
Setting Selected to CopyPreset
Settings
Reset to
Default
Figure 7-1 Reciprocator Preset Screen
Fixed Mode Settings
See Figure 7-2.
The Gun On/Off Up/Down settings are relative to the part edge. Positive
settings extend the spray by turning the guns on BEFORE the part edge
and off AFTER the part edge. Negative settings restrict the spray by turning
the guns on AFTER the part edge and off BEFORE the part edge.
The Top/Bottom Turn-Around setpoints are measured from the Home
position.
Reciprocator Speed can be set for both Fixed, No Synchronization and
Variable, No Synchronization modes. If the mode is Synchronized, then the
speed is controlled by the conveyor speed and other configuration settings
and cannot be set for presets.