Monitoring Operation
9-5
Part 1056418-07
E 2019 Nordson Corporation
Single Gun Status
See Figure 9-3. Touch a Gun button to open the Gun Control screen for
that gun. The Gun Status area of the screen shows you the:
S part/preset being sprayed
S flow-rate air flow (dark blue) and atomizing air flow (light blue) for
standard guns
S powder flow setpoint and actual pump air flow (dark blue) and pattern air
flow (light blue) for Prodigy guns
S electrostatic outputs
S gun type
S fault code, if a gun-related fault occurs
S percent adjust status: If Δ% (delta %) symbols appear below the flow
bar graphs, then the flow is being adjusted automatically with the
Percent Adjust function.
NOTE: Gun-related faults are faults that occur in the gun’s voltage
multiplier, cable, gun control card, or iFlow module. If a gun-related fault
occurs, the gun button will blink yellow.
Part
Being
Sprayed
Percent
Adjust
ON Indicator
Flow Rate
Air Flow
Atomizing
Air Flow
mA Output
kV Output
Gun
Hourmeter
Standard Guns Prodigy Guns
Fault Code
Powder
Flow
Pattern
Air Flow
Powder
Flow
Setpoint
Figure 9-3 Global Status Screen
Gun Hourmeter
The Gun Hourmeter button on the Gun Control screen opens the
hourmeter screen for the gun. This screen displays
S gun and pump hours on since the last maintenance reset.
S maintenance hours for the guns (also for Prodigy pumps).
S gun and pump total hours.
Gun and pump maintenance hours are reset from the Configure Hourmeter
screen.