Operation
8-15
Part 1056418-07
E 2019 Nordson Corporation
Reciprocator Controls
See Figure 8-11. Touch the reciprocator images on the Main screen to open
the Reciprocator Control screens.
Reciprocator Operating Modes
NOTE: Reciprocator operating mode can also be set from the Global
Control screen (page 8-5).
Auto: The reciprocator moves automatically according to the default or
preset settings.
Manual: Shuts off the reciprocator and activates the Jog buttons so you
can move it manually.
Off: Shuts off the reciprocator.
Control Screen Indicators and Functions
Manual/Off Mode Locks: Use these to lock the reciprocator in either
Manual mode or Off mode. When locked, the reciprocator cannot be forced
into Auto mode from the Global Control screen or by an external signal.
Lockout Indicator: If not grayed out, the reciprocator is locked out from
the configuration screen. When locked out, it cannot be operated from this
control screen or by an external signal.
WARNING: Whenever making adjustments or repairs to a positioner or
reciprocator, always disconnect power, then tag and physically lock out the
power source.
Home: Touching the Home button moves the reciprocator to the Home
position, which is 1.0 inch off the top limit switch.
Top and Bottom Soft Limits: These are set during Reciprocator
Configuration. They prevent the reciprocator from tripping the top and
bottom limit switches.