Ethernet and Gun Mover Configuration
4-5
Part 1056418-07
E 2019 Nordson Corporation
Node Configuration
Refer to Table 4-1 and Figure 4-4. The nodes are devices on the Ethernet
network such as the positioner, reciprocator, or analog scanner controllers.
Touch the Node Configuration button on the Network Status screen to
open the Node Configuration screen.
Security Login: This button opens the Login screen so Nordson CSRs can
log in and change settings.
1. Enter the MAC Address, TCP/IP Address, and Machine Type for each
node on the network, as described in Table 4-1. If you make an invalid
entry the field will turn yellow.
When entering the machine type, select the field, then use the rotary dial
to toggle through the possible selections:
Heading
GP1 through GP4 (positioners 1 through 4) GP1_RC1 (positioner 1 and reciprocator 1)
RC1 through RC4(reciprocators 1 through 4) GP2_RC2 (positioner 2 and reciprocator 2)
GP1_GP2 (positioners 1 and 2) GP3_RC3 (positioner 3 and reciprocator 3)
GP3_GP4 (positioners 3 and 4) GP4_RC4 (positioner 4 and reciprocator 4)
RC1_RC2 (reciprocators 1 and 2) PE (scanners)
RC3_RC4 (reciprocators 3 and 4)
Configure the positioners first, always entering them in numerical order. If
the system has reciprocators but no positioners, then configure the
reciprocators first, always entering them in numerical order.
If two positioners or reciprocators use the same controller, select a
combination such as GP1_GP2 or RC1_RC2. If one controller controls a
positioner and reciprocator, the system always assumes that reciprocator 1
is mounted on positioner 1 (GP1_RC1).
2. Touch the Send IP Address button or the Save button.
S The Send IP Address button sends the IP addresses to the
controllers.
S The Save button saves the data entries and sends the IP addresses
to the controllers if not done already.
iControl Versions Below 3.0
When you touch the IP Send or Save button, you are prompted to cycle
power on the node controllers by three messages. If you do not cycle
power correctly, the system will not be able to communicate with the nodes
on the network.
iControl Version 3 and Above Procedure
When you touch the IP Send or Save button, the following dialog box opens
and stay open until it is closed. You must now cycle power on the
controllers.