Ethernet and Gun Mover Configuration
4-1
Part 1056418-07
E 2019 Nordson Corporation
Section 4
Ethernet and Gun Mover Configuration
Contents
Introduction 4-2.............................................
System Configuration Screen 4-2..............................
Ethernet Network Configuration 4-3............................
Network Status Functions 4-3..............................
Host Configuration 4-4.....................................
Node Configuration 4-5....................................
iControl Versions Below 3.0 4-5..........................
iControl Version 3 and Above Procedure 4-5...............
Positioner Configuration 4-8..................................
Operating Mode Buttons and Locks 4-9......................
Actual Position 4-9........................................
Setting Encoder Resolution 4-9.............................
Setting Zero and Home Positions 4-10........................
Standard Positioner Configuration Settings 4-10...............
Application-Specific Positioner Configuration Settings 4-12......
Positioning Guns on Horizontal Positioners 4-12...............
Positioning Guns on Vertical Positioners 4-12..................
Move Settings 4-14.........................................
Normal Default Move Example 4-15........................
Lancing Default Moves Example 4-16......................
Reciprocator Configuration 4-18................................
Operating Mode Buttons and Locks 4-19......................
Nordson Service Settings 4-19...............................
Encoder Resolution and Maximum Speed 4-19..............
Accel/Decel Time 4-20...................................
Turn-Around Offset 4-20..................................
Standard Reciprocator Configuration Settings 4-21.............
Application-Specific Reciprocator Settings 4-22................
Operation Mode Settings 4-22.............................
Reciprocator Speed Settings 4-22.........................
Fixed Mode 4-23........................................
Oscillator Mode 4-24.....................................
Variable Modes 4-24.....................................
Air Flow Percent Adjust Control 4-26.........................
Analog Scanner Configuration 4-28.............................
Analog Scanner Enable 4-28................................
Single In/Out Positioner Scanner Configuration 4-29............
Dual In/Out Scanner Configuration 4-30.......................
Vertical Scanner Configuration 4-30..........................
Vertical Offset (Reciprocators Only) 4-31....................
Setting the Zero Offset Override 4-32.......................