Monitoring Operation
9-8
Part 1056418-07
E 2019 Nordson Corporation
Color Change Monitoring (contd)
4. All guns purging: Indicator 3 lights green.
5. Clean cycle running: Indicator 4 lights green.
6. Arch cleaning (SpeedKing booth only): Indicator 5 lights green.
7. Arch cycle complete: Indicator 6 lights green.
When the color change operation is complete, touch the Park Button to
return the system to normal.
Cleaning
Icon
Cycle
Indicators
Park Button
Figure 9-7 Color Change Status Indicators
Alarms
Alarms and fault codes alert you to problems with the iControl system.
Fault Codes
If a problem occurs that is related to the spray gun voltage multiplier, cable,
gun control card, or iFlow module, the gun button will blink yellow, and a red
indicator and Fault Code will appear on the gun control screen. A fault
message will also appear on the Alarm screen.
Refer to the Troubleshooting section of your console hardware manual for
an explanation of the fault codes and suggested methods to correct the
faults. Contact your Nordson representative or call the Finishing Customer
Support Center at 800-433-9319 for help.
Alarm Screen
The Alarm Button blinks yellow if a fault occurs. Touching the Alarm
Button opens the Alarm screen. See Figure 9-8.
To reset all active faults, touch the Reset All Button. If the problem that
caused a fault is not corrected, the fault will reappear.