Positioner Preset Settings
6-5
Part 1056418-07
E 2019 Nordson Corporation
Variable Positioning Contouring
Minimum: Lead 2, Lag 2, Gun-to-Part 2
Default: Lead 5, Lag 5, Gun-to-Part 10
Preset: Lead 4, Lag 4, Position 8 Variable
1. See Figure 6-3. The positioner waits at the configured position.
2. Four inches from the leading edge of the part, the guns are moved back
to 10 inches from the part.
3. Four inches from the change in part width, the guns are moved back to
maintain the gun to part distance.
4. Four inches after the change in part width the guns are moved forward
to maintain the distance.
5. Four inches after the trailing edge of the part, the guns are moved
forward to wait for the next part.
Lead
Lag
12345
Lag
Lead
G-P
G-P
G-P
Steps
Figure 6-3 Variable Positioning Contouring