EasyManua.ls Logo

Nordson iControl Series - Zone Assignment and Trigger Prevention; Zone Assignment for Spray Guns; Using Zones to Prevent Triggering

Nordson iControl Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spray Gun Preset Settings
5-18
Part 1056418-07
E 2019 Nordson Corporation
Zone Assignment
When a part is detected by a zone photoeye, the spray guns assigned to
that zone by the preset for that part are triggered on when the part passes
by the guns. Normally spray guns are assigned to the zone the guns are
physically in, but can be assigned to any zone.
CAUTION: Do not change zone assignments while parts are moving
through the booth. Doing so could cause erratic operation.
Using Zones to Prevent Triggering
To prevent a spray gun from triggering for a particular part, set the zone
assignment to zero for the preset. The gun will not be triggered when that
part passes by.
Conveyor Direction
Zone
Gun Control Screen
Zone
Preset Table Screen
1
2
3
4
5
6
7
8
Zones Guns
Zone Assignment
1
2
0
4
5
6
7
8
Figure 5-16 Zone Assignments