Ethernet and Gun Mover Configuration
4-6
Part 1056418-07
E 2019 Nordson Corporation
The process works as follows:
S All network traffic is suspended
S User cycles power on the controllers
S After the first timeout completes (10 seconds), the nodes are pinged,
and the screen reports who is online.
S Enter idle state (5 seconds) then repeat ping.
Cycle controller power and wait until the indicators for the configured
controllers change to green, which indicates that they have recognized the
ping. Once the indicators are green, you can close the dialog and exit the
Node Configuration screen.
Table 4-1 Node Configuration Data
Setting Description
MAC
Address
Each node on the network has a unique MAC address. The address is on the manufacturer
label attached to the FieldBus couplers or controllers. Enter this number into the MAC
address fields.
TCP/IP
Address
Each node must have a unique TCP/IP address. Recommended addresses:
Booth 1: Booth 2:
First device: 192.162.1.10 First device: 192.162.1.20
Second device: 192.162.1.11 Second device: 192.162.1.21
and so on. and so on.
NOTE: If the system contains two or more booths that share part dimension scanners, give
the scanner controller (PE) the same address on both consoles.
Machine
Type (M)
Touch the Machine Type field and select the device functions from the drop-down list.
GP: Positioner RC: Reciprocator or Oscillator
FC: Feed Center PE: Analog Scanner, used with positioners and reciprocators
NOTE: Some machines can have more than one function, such as an in/out positioner and
oscillator or reciprocator (GP1_RC1).