Troubleshooting
6-23
Part 1120277_01
E 2012 Nordson Corporation
T.1.1
+
--
+
--
Is the green power LED on
the display/CPU board
illuminated?
+
--
Is the voltage across TP7
(+) and TP2 (-) on the main
board between 4.75 and
5.25 VDC?
Is the voltage across
TP2 (+) and TP4 (-) on the
display/CPU board
between 4.75 and
5.25 VDC?
+
--
Is the red CPU fault LED
illuminated?
Replace the main board.
Check the ribbon cable or
replace the display/CPU
board.
Replace the display/CPU
board.
+
--
+
--
Does changing the main
board correct the problem?
Secure or replace the
cable.
Is the ribbon cable
between the main board
and the display/CPU board
loose or visibly damaged?
Secure or replace the
cable.
+
--
Contact Nordson for
technical assistance.
Replace the display/CPU
board.
Does changing the
display/CPU board correct
the problem?
Stop.
+
--
Is LED DS15 on the main
board illuminated?
Replace the main board.
+
--
Is the ribbon cable
between the main board
and the display/CPU board
loose or visibly damaged?
Control panel is not
illuminated >
Disconnect switch is on >
DS4 is illuminated