Technical Data
8-8
Part 1120277_01
E 2012 Nordson Corporation
Melter Configuration Code
See Figure 8-5. A code that represents the configuration of the melter is
stamped on the equipment identification plate. To determine the
configuration of your melter, obtain its configuration code and refer to
Table 8-1 to interpret the code.
Figure 8-5 Unit identification plate
Table 8-1 Melter Configuration Code Values
Box Description Code Values
1
Identifies the equipment as a
PURBlue 4 melter
PURBLUE 4 = PURBlue 4 melter
2 Adhesive slug size A = 134 mm diameter (2 kg)
3 Voltage 1 = 240 VAC Delta or 400 VAC Wye
4 Pump
E = PR12M1 pump (1.86 cc/rev)
F = PR12M2 pump (3.71 cc/rev)
5 Thermostat M = 350 _F
6 Pressure control
X=ManualPCV
F=Flowcontrolbypass
7 Cooling fan X = no cooling fan
8 Melter type HO = high-output