Reservoir key
Left display and scroll key
Enter key
Operation
4-23
Part 1120277_01
E 2012 Nordson Corporation
Adjusting Component Temperatures
You can adjust the setpoint temperature of heated components using the
following methods:
S Global—The reservoir and all hoses and guns are set to the same
setpoint temperature.
S Global-by-component group—All of the hoses or all of the guns are
set to the same setpoint temperature.
S Individual Component—The setpoint temperature of the reservoir
and each hose and gun is adjusted independently.
Before adjusting setpoint temperatures, confirm that each hose/gun pair
is connected to the correct hose/gun receptacle. For example, hose/gun pair
1 should be connected to the receptacle 1. Refer to Melt Plate Operation and
More About Heated Components earlier in this section for information about
hose/gun positions.
To adjust setpoint temperatures using the global method
1. Press and hold the Reservoir key for three seconds.
The left display flashes 1.
2. Scroll the left display to 0 (flashing).
The right display i ndicates all dashes (----) and the LEDs on all of
the component keys turn green.
3. Press the Enter key.
The right display flashes.

Table of Contents