Operating Parameters
B-8
Part 1120277_01
E 2012 Nordson Corporation
Temperature Control
20 Temperature Units
Description: Sets the units for t emperature display.
Value: C (degrees Celsius) or F (degrees Fahrenheit)
Resolution: 1degree
Default Value: C
Format:
Use:
21 Over Temperature Delta
Description: The number of degrees that the temperature of any component
can increase over its assigned setpoint temperature before an
over temperature fault (F3) will occur.
Value: 5 _C(10_F) to 60 _C (110 _F)
Resolution: 1_C
1_F
Default Value: 15 _C(25_F)
Format:
Use:
22 Under Temperature Delta
Description: The number of degrees that the temperature of any component
can decrease from its setpoint temperature before an under
temperature fault (F2) occurs.
Value: 5 _C(10_F) to 60 _C (110 _F)
Resolution: 1_C
1_F
Default Value: 25 _C(50_F)
Format:
Use: